Outdoor C&I Energy Storage Cabinet
215 / 261 kWh outdoor integrated cabinet with intelligent liquid cooling, 125 kW PCS, and aerosol fire protection.
The HLY-ELS series is the premier turnkey energy storage solution for manufacturing factories, commercial complexes, cold-storage warehouses, and EV charging stations. Integrating liquid-cooled 314Ah LFP battery modules, a 125kW bidirectional PCS, intelligent HVAC, and aerosol fire suppression into a compact IP55 outdoor cabinet, it scales seamlessly to multi-megawatt microgrids.
Request Wholesale Pricing, CAD SLD & Datasheet
Get direct manufacturer pricing with zero trading markups, single-line diagrams, UN38.3 test summaries, and custom OEM/ODM silkscreen terms.
Designed for Zero-Downtime High Yield Operations
Industrial Liquid Cooling Uniformity
Precision liquid circulation keeps cell-to-cell temperature delta ≤ 2.5°C across the high-voltage pack, extending battery service life by 35% and preventing thermal hot-spots.
Integrated PCS & Bidirectional AC Grid Coupling
Combines 125kW bidirectional PCS and 261kWh battery in a single footprint. Delivers 400V three-phase output with <2.5% THDi and adjustable power factor (-1 to +1).
Three-Tier Active Fire Defense Architecture
Early thermal runaway gas sniffing, pack-level compartment isolation, and automated total-flooding aerosol fire suppression comply with NFPA 855 and IEC 62619.
Outdoor C&I Energy Storage Cabinet (HLY-ELS 215 / 261 kWh)
All electrical, mechanical, and thermal ratings are verified in accordance with factory quality control protocols and IEC standards.
| 1. Battery Storage Subsystem | |
|---|---|
| System Model / Series | HLY-ELS26001Y261K (HLY-ELS Series) |
| Nominal Battery Energy | 261.25 kWh (Flagship) / 215.04 kWh (Standard) |
| Cell Specification & Layout | LFP-3.2V-314Ah (260S1P High-Voltage String) |
| Nominal DC Bus Voltage | 832.0 VDC (261K) / 768.0 VDC (215K) |
| Operating DC Voltage Window | 702.0 VDC ~ 949.0 VDC |
| Nominal Charge / Discharge Rate | 0.5C Continuous Rating |
| Cycle Durability at 25°C | ≥ 8,000 Cycles @ 0.5C, 25±2°C, ≥ 70% EOL |
| Battery Side Thermal Control | Intelligent Liquid Cooling & Heating (50% Ethylene Glycol) |
| 2. Inverter PCS & Grid Intertie Subsystem | |
| Rated AC Output Power | 125 kW (261K) / 100 kW (215K) |
| Rated AC Output Current | 180 A (125kW) / 144 A (100kW) |
| Grid Nominal Voltage & Phase | 400 VAC (3L + N + PE Three-Phase) |
| Grid Frequency Tolerance | 50 Hz / 60 Hz (±2.5 Hz adaptive) |
| Total Harmonic Distortion (THDi) | < 2.5% at rated full power |
| Power Factor Adjustment Range | -1 (Leading) ~ +1 (Lagging) continuously adjustable |
| PCS Thermal Dissipation | Forced air cooling with intelligent fan modulation |
| Grid-Tied to Off-Grid Transfer | < 10 ms (Seamless industrial UPS islanding) |
| 3. Enclosure, Dimensions & Safety Construction | |
| Cabinet External Dimensions (W×D×H) | 1000 × 1350 × 2390 mm |
| Total Equipment Operating Weight | 2600 ± 150 kg (Ready for crane or forklift drop) |
| Ingress Protection Class | IP55 (Outdoor all-weather installation) |
| Corrosion Protection Rating | C3 Standard (C4 / C5 Marine-grade optional) |
| Active Fire Extinguishing | Automated Total-Flooding Aerosol Fire Suppression System |
| External Sprinkler Interface | Integrated top/side water sprinkler flange pipe |
| Emergency Safety Disconnect | Physical external E-Stop button + internal DC breaker with shunt trip |
| 4. System Communication & Energy Management (EMS) | |
| External Communication Interfaces | Industrial Ethernet (RJ45) / RS485 / Optical Fiber |
| Supported Protocols | Modbus TCP / Modbus RTU / MQTT / IEC 60870-5-104 |
| HMI & Cloud Portal | 10-inch Industrial Touchscreen + Remote Cloud Web/App Telemetry |
| Control Modes | Peak Shaving, TOU Arbitrage, Demand Response, Microgrid Islanding |
| 5. Environmental Operating Range & Standards | |
| Operating Ambient Temperature | -20°C ~ +55°C (Internal climate controlled) |
| Storage Temperature Range | -20°C ~ +45°C (30%~50% SOC) |
| Operating Humidity Range | 0% ~ 95% RH (Non-condensing) |
| Maximum Operating Altitude | ≤ 2,000 m (Derating applicable above 2,000m) |
| Compliance & Safety Norms | IEC 62619, IEC 63056, IEC 62477, GB/T 36276, UN38.3, CE EMC/LVD |
Native Auto-Matching Protocol Matrix
Zero-debugging closed-loop communication handshake with tier-1 hybrid inverter brands.
Ready to Configure Your Project or Request Wholesale Distributor Terms?
Our technical engineering team provides custom electrical Single-Line Diagrams (SLD), bill-of-materials optimization, and port delivery schedules within 12 hours.